Inverters Solar 6000w
The system power is between 40-60% of the rated power of the inverter, with the highest efficiency and the longest life. In order to give the best play to the performance of the inverter, different components and inverters have different ratios according to different lighting conditions In the first-class illumination area, the average sunshine time is more than 5 hours, and the power generation time is calculated as 10 hours per day. It is suggested that the components and inverters should be configured 1:1, and the average power is about 50%. In the second-class illumination area, the average sunshine time is 4 hours, and the power generation time is calculated as 9 hours per day. It is suggested that the assembly and inverter should be configured as 1.1:1,(4*1.1)/9, and the average power is about 49%. In the light area with the average sunshine time of 3.5 hours in the third class, the power generation time is calculated as 8.5 hours per day. It is suggested that the assembly and inverter should be configured as 1.2:1,(3.5*1.2)/8.5, and the average power is about 49.4% In the three types of light areas where the average sunshine time is less than 3 hours, the power generation time is calculated as 8 hours per day. It is suggested that the components and inverters should be configured as 1.3:1,(3*1.3)/8, and the average power is about 48.75%